Use the State 40-gallon gas water heaters comparison chart to select the most suitable model for heating potable water in residential applications. In the comparison charts you can find the main technical data and features of the State tank-type gas heaters. Select the best models including Energy Star approved ones.
Specs. --------- Model |
Input (Btu) x1000 |
First Hour Delivery (GPH) |
Recovery Rate (90F) (GPH) |
Energy Factor |
Approx. Height/ Type (Inch) |
Vent Type |
Warr anty |
Premier High Efficiency | |||||||
GP6 40 YPCT | 40 | 70 | 43 | 0.70 | 62 Tall |
A | 6 |
High Efficiency | |||||||
GS6 40 YBFT | 40 | 67 | 42 | 0.67 | 58 Tall |
FD | 6 |
GS6 40 YBFS | 40 | 67 | 42 | 0.67 | 48 Short |
FD | 6 |
Premier |
|||||||
GPX 40 YXRT* | 40 36 |
70 | 41 | 0.63 | 62 Tall |
A | 10 |
Select High Efficiency | |||||||
GS6 40 YOCT* | 40 37 |
70 | 41 | 0.62 | 62 Tall |
A | 6, 10 |
GS6 40 YOCS* | 40 37 |
67 | 41 | 0.62 | 52 Short |
A | 6, 10 |
Select High Output | |||||||
GS6 40 YRRT* | 50 47 |
88 | 48 | 0.60 | 62 Tall |
A | 6, 10 |
Select | |||||||
GS6 40 YBRT* | 40 37 |
70 | 41 | 0.59 | 62 Tall |
A | 6, 10 |
GS6 40 YBRS* | 40 37 |
66 | 41 | 0.59 | 52 Short |
A | 6, 10 |
Select Ultra Low NOx | |||||||
GS6 40 UBRT | 40 | 65 | 41 | 0.59 | 62 Tall |
A | 6 |
GS6 40 UOCT | 40 | 70 | 41 | 0.62 | 62 Tall |
A | 6 |
Select Power Direct Vent | |||||||
GS6 40 YBPDT* | 40 36 |
70 | 41 | 0.60 | 57 | PDV | 6 |
Select Power Vent | |||||||
GS6 40 YBVIT* | 40 | 69 | 44 | 0.65 | 63 Tall |
PV | 6 |
GS6 40 YBVIT 2* |
40 | 70 | 44 | 0.67 | 63 Tall |
PV | 6 |
GS6 40 YRVIT* | 50 | 80 | 53 | 0.65 | 63 Tall |
PV | 6 |
Select Direct Vent | |||||||
GS6 40 YBDS* | 38 | 73 | 41 | 0.62 | 68 Tall |
DV | 6 |
Select Manufactured Housing | |||||||
GS6 40 YOMT | 35.5 | 57 | 37 | 0.59 | 62 Tall |
A | 6 |
PR6 40NHDST2 | 32 | 64 | 33 | 0.59 | 56 | DV | 6 |
Premier Side Loop High Efficiency | |||||||
GPX 40 YXRT L* |
40 | 70 | 41 | 0.63 | 62 Tall |
A | 10 |
Select Side Loop | |||||||
GS6 40 YBRT L* |
40 | 40 | 41 | 0.59 | Tall | A | 6 |
GS6 40 YOCT L* |
40 | 40 | 41 | 0.62 | Tall | A | 6 |
GS6 40 YRRT L* |
50 | 40 | 51 | 0.59 | Tall | A | 6 |
GS6 40 YBPDT L* |
40 36 |
70 | 41 | 0.60 | Tall | PDV | 6 |
GS6 40 YRVIT L* |
50 | ? | 51 | 0.65 | Tall | PV | 6 |
GS6 40 YBDS L* |
38 | ? | 41 | 0.62 | Tall | DV | 6 |
Vent type:
A-Atmospheric, PV-Power Vent, DV-Direct Vent, FD- Flue Damper, PDV-Power Direct Vent
Gas type:
N - Natural gas, P - Propane ( * change Y to H for propane type).
Example: GS6 40 YBPDT is natural gas, GS6 40 HBPDT is propane water heater).
Models with the energy factor, EF, of 0.67 and over are Energy Star.
Specs. --------- Model |
Anode Rod |
Advanced Diagnostic |
Intelligent Control Logic |
Self Cleaning system | Low NOx Design |
Igniter |
Premier High Efficiency | ||||||
GP6 40 YPCT | Powered | Yes | No | Yes | Yes | Hot Surface |
High Efficiency | ||||||
GS6 40 YBFT | 1 (Al) | Yes | Yes | Yes | Yes | Electronic |
GS6 40 YBFS | 1 (Al) | Yes | Yes | Yes | Yes | Electronic |
Premier | ||||||
GPX 40 YXRT | 1 (Mg) | No | No | Yes | Yes | Piezo |
Select High Efficiency | ||||||
GS6 40 YOCT | 1 (Al) | No | No | Yes | Yes | Piezo |
GS6 40 YOCS | 1 (Al) | No | No | Yes | Yes | Piezo |
Select High Output | ||||||
GS6 40 YRRT | 1 (Al) | No | No | Yes | Yes | Piezo |
Select | ||||||
GS6 40 YBRT | 1 (Al) | No | No | Yes | Yes | Piezo |
GS6 40 YBRS | 1 (Al) | No | No | Yes | Yes | Piezo |
Select Ultra Low NOx | ||||||
GS6 40 UBRT | 1 | No | No | Yes | Ultra | Piezo |
GS6 40 UOCT | 1 | No | No | Yes | Ultra | Piezo |
Select Power Direct Vent | ||||||
GS6 40 YBPDT | 1 (Al) | No | Yes | Yes | Yes | Piezo |
Select Power Vent | ||||||
GS6 40 YBVIT | 1 (Al) | No | Yes | Yes | Yes | Piezo |
GS6 40 YBVIT 2 | 1 (Al) | No | Yes | Yes | Yes | Piezo |
GS6 40 YRVIT | 1 (Al) | No | Yes | Yes | Yes | Piezo |
Select Direct Vent | ||||||
GS6 40 YBDS | 1 | No | No | Yes | Yes | Piezo |
Select Manufactured Housing | ||||||
GS6 40 YOMT | 1 (Al) | No | No | Yes | Yes | Piezo |
PR6 40 NHDST2 | 1 (Al) | No | No | Yes | Yes | Piezo |
Premier Side Loop High Efficiency | ||||||
GPX 40 YXRT L | 1 (Al) | Yes | Yes | Yes | Yes | Piezo |
Select Side Loop | ||||||
GS6 40 YBRT L | 2 (Mg) | No | No | Yes | Yes | Piezo |
GS6 40 YOCT L | 2 (Mg) | No | No | Yes | Yes | Piezo |
GS6 40 YRRT L | 2 (Mg) | No | No | Yes | Yes | Piezo |
GS6 40 YBPDT L | 2 (Mg) | No | No | Yes | Yes | Piezo |
GS6 40 YRVIT L | 2 (Mg) | No | Yes | Yes | Yes | Piezo |
GS6 40 YBDS L | 2 (Mg) | No | Yes | Yes | Yes | Piezo |
The above comparison chart shows that most State gas water heaters have one anode rod, which is important to fight the aggressive water action, while those with two rods have better protection. Also, every unit has the Pexan dip tube, which uses the advanced self-cleaning system (specially designed dip tube that provides the turbulent water flow for sediment reduction).
Another major difference between standard and advanced models is in features such as the Intelli-Vent gas control valve that provides precise temperature, better performance, and gas valve with diagnostics for easy troubleshooting, while the appliances with silicon nitride hot surface ignitors are made for harsh conditions.